Inspection Date 9/11/2019
Final Score @ Grade
20
General CommentsContrasting color bands are fading. Bands to not extend all the way to the pool walls. Prior to 2020 pool permit being issued, provide at least 2" contrasting color band that extends to pool walls and edge of steps. Immediate suspension issued. 22) Contact Will Harrison (704-507-6824) for reinspection when phone is fixed. Please ensure that phone number and address that 911 has is correct and matches what's posted on the emergency phone signage.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Inconsistent record keeping. Missing records from most of September. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Most ladders missing endcaps. .2521 Install ladders per manufacturer instructions.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some deck chairs too close to the pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No Emergency phone nort working. .2530(f) Emergency phone shall remain operable. 2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Immediate suspension item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not working in the chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Multiple leaks in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. Fan not working in the pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap.