Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSAILPOINTE AT LAKE NORMAN
Address21338 NAUTIQUE BLVD
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/16/2019
Final Score @ Grade
12
General CommentsContrasting colorband on steps fading. Recommend painting at least 2" wide contrasting color band along leading edge of the steps. Permit will be available on our website, Meckpools.Charmeck.org in the next week or two. Print a copy to post in the pool area. Pool is permitted for night swimming.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No main drain checks. No place on new pool log sheet. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator plans to start using state log sheet.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Two ladders missing endcaps. Some ladders too far from pool wall. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. .2521 Install ladders per manufacturer instructions.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fans in pump room and chemical storage room not functioning. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Toilet paper dispenser missing in men's restroom. .2626(l) Provide toilet paper and dispensers in restrooms.