Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSAILPOINTE AT LAKE NORMAN
Address21338 NAUTIQUE BLVD
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/2/2018
Final Score @ Grade
20
General CommentsPool open after dark. Recommend posting pool hours. Night swimming inspection scheduled for 6:15 AM on Friday. Permit issued.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladders missing endcaps. Ladders too far from pool wall. Maintain ladders between 3 and 6 inches from the pool wall and in good condition.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope too short. Provide 38 foot throw rope. Corrected by operator.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Mulch built up around the fence. Fence as short as 43 1/2". Maintain fence at least 48" high w/ no gaps > 4" through the fence.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Corrected by operator.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fans not working in pump room and chemical storage room. Provide either cross or forced air ventilation. Door to chemical storage room removed. Provide separate chemical storage room. Chemicals stored in pump room. Store chemicals in chemical storage room.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash a direct connection to drain. Provide air gap for backwash.