11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladders missing endcaps. Ladders too far from pool wall. Maintain ladders between 3 and 6 inches from the pool wall and in good condition. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope too short. Provide 38 foot throw rope. Corrected by operator. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Mulch built up around the fence. Fence as short as 43 1/2". Maintain fence at least 48" high w/ no gaps > 4" through the fence. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Corrected by operator. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fans not working in pump room and chemical storage room. Provide either cross or forced air ventilation.
Door to chemical storage room removed. Provide separate chemical storage room.
Chemicals stored in pump room. Store chemicals in chemical storage room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash a direct connection to drain. Provide air gap for backwash. |