11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Handrail into pool loose at time of inspection. Keep tight and in good repair. Operator tightened and corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Front gate has horizontal protrusion creating handhold less than 45". Same gate not staying latched each time closed. .2528(b) Horizontals shall not be located less than 45" in height. .2537(b) All gates and doors shall be self-closing, self-latching.
**30 Day Intent to Suspend item. Contact Marie Daley at 704-507-6806 when corrected to lift ITS. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Vacuum connector still in place at time of inspection. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Operator placed cap on opening and corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Lighting out in chemical storage. Items around piping in pump room. Condensation creating water on floor in pump room.
.2533(d) Pump room floor shall be kept dry and free of standing water. .2534(6) Provide sufficient lighting in chemical storage room.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |