Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePINEVILLE PLACE
Address12821 MEADOW CREEK LANE
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/10/2026
Final Score @ Grade
10
General CommentsConducted inspection with CPO. Pool remains on A status and in good standing. Permit Restriction: Flow meter must remain operable. Flow required no greater than 150 gpm due to drain cover flow restriction. Suction Hazard.Note: EMBLEM ON POOL FLOOR APPROVED WITH LRV OF 80 - DOCUMENTATION PROVIDED Const. Date: 1/1/1985 Rope Length: 50' Night Swim?: N

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. One rubber end cap missing from one ladder. Replace
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Provide no openings in fence and/or gate that allows passage of a four inch diameter sphere. Some parts of the back fence and fence beside building bent/damaged creating openings of greater than 4 inches. Pre 2010 pool. Operator bent the rungs back into place. No permit action.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Lights out in chemical room. No 3' clearance around all equipment. Ventilation not working in chemical or pump room. Pool built '85. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No floor drains in restrooms. .2526(c) Floor drains shall be provided in restrooms.