Premises Information

Return to Inspections
NamePINEVILLE PLACE
Address12821 MEADOW CREEK LANE
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/18/2023
Final Score @ Grade
12
General CommentsBuoy starting to wear, beckets starting to detach. Advised replacing (w/ USCG approved buoy) before in disrepair to avoid permit action at future inspection and in case of emergency. Inspection with Camilo Hermosillo. No Night Swimming

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
10 2 Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints No No No Safety rope at breakpoint floats not spaced apart at time of inspection. .2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. Operator adjusted floats and corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder missing rubber stopper. Ladder greater than 6" from wall. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. .2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate gap greater than 4”. Some gaps in fencing and gate greater than 4" where rods are bent. Pool built '85. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Operator bent rods and corrected gate gaps greater than 4".
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Lights out in pump and chemical room. No 3' clearance around all equipment. Ventilation not working in chemical or pump room. Pool built '85. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2533(b) Provide sufficient lighting in pump room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap. Pool built 85.