8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Some debris in skimmers at time of inspection.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected. |
|
10
|
2
|
Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints |
No |
No
|
No |
Safety rope at breakpoint missing at time of inspection. .2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less.
Operator had pool voluntarily closed at time of inspection, but rope with floats were in equipment room. Operator obtained rope and corrected. |
|
13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
Contrasting color band on stair tread over 2”, almost 3” to edge of pool wall. .2521(b) Provide at least 2" contrasting color band to edge of stair treads.
.2521(b) Provide at least 2"x 2" tile for contrasting color band within 1" of adjacent tiles and edge of the stair tread.
*Permit item. 30 Day Intent to Suspend (ITS) item, time was allowed from last inspection. Permit cannot be renewed without compliance on this item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gate gap greater than 4”. Some gaps in fencing and gate greater than 4" where rods are bent. Pool built '85.
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Operator bent rods and corrected gate gaps greater than 4". Back corner area of fencing still missing rod with gap over 4”. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Lights out in pump and chemical room. Chemicals stored in pump room. No 3' clearance around all equipment. Ventilation not working in chemical or pump room. Pool built '85. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(b) Provide sufficient lighting in pump room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap. Pool built 85. |