Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePINEVILLE PLACE
Address12821 MEADOW CREEK LANE
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/6/2023
Final Score @ Grade
18
General Comments30 Day Intent to Suspend (ITS) issued for contrasting color bands at steps. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Note: Phone connection breaking up some and address did not indicate “Pool phone”, but another apartment number. Phone still operable and correct physical address, so no permit action taken, but advised speaking with the phone company and 911 to ensure exact location is correct and clearly audible for pool, in case of emergency. Keep buoy and rope on deck. Discussed record keeping for maintenance (backwash, chemicals, vacuum, etc should be notes not “check mark”). No Night Swimming

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Some debris in skimmers at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected.
10 2 Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints No No No Safety rope at breakpoint missing at time of inspection. .2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. Operator had pool voluntarily closed at time of inspection, but rope with floats were in equipment room. Operator obtained rope and corrected.
13 4 Pool maintenance: contrasting band on steps and benches No No No Contrasting color band on stair tread over 2”, almost 3” to edge of pool wall. .2521(b) Provide at least 2" contrasting color band to edge of stair treads. .2521(b) Provide at least 2"x 2" tile for contrasting color band within 1" of adjacent tiles and edge of the stair tread. *Permit item. 30 Day Intent to Suspend (ITS) item, time was allowed from last inspection. Permit cannot be renewed without compliance on this item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate gap greater than 4”. Some gaps in fencing and gate greater than 4" where rods are bent. Pool built '85. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Operator bent rods and corrected gate gaps greater than 4". Back corner area of fencing still missing rod with gap over 4”.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Lights out in pump and chemical room. Chemicals stored in pump room. No 3' clearance around all equipment. Ventilation not working in chemical or pump room. Pool built '85. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(b) Provide sufficient lighting in pump room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap. Pool built 85.