Return to Inspections
NamePINEVILLE PLACE
Address12821 MEADOW CREEK LANE
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/12/2022
Final Score @ Grade
16
General CommentsIntent to Suspend (ITS) issued for tiling missing on pool wall. Permit expires April 30, 2022. Correct before this date to keep active permit. Contact Marie Daley at 704-507-6806 went into compliance to lift ITS. Changed to “W” ITS status Allowing until 2023 permit to correct contrasting color bands.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Tiling of pool wall cracked out. .2537(14) Keep pool surface and pool floor free of debris and in good repair. *Permit item.
13 4 Pool maintenance: contrasting band on steps and benches No No No Contrasting color band on stair tread over 2”, almost 3” to edge of pool wall. .2521(b) Provide at least 2" contrasting color band to edge of stair treads. .2521(b) Provide at least 2"x 2" tile for contrasting color band within 1" of adjacent tiles and edge of the stair tread. *Permit item. Allowing until 2023 to correct due to maintenance required to address and not noted previously when work was completed.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate gap greater than 4”. Some gaps in fencing and gate greater than 4" where rods are bent. Pool built '85. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Operator bent rods and corrected gate gaps greater than 4". Back corner area of fencing still missing rod with gap over 4”.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Lights out in pump and chemical room. Chemicals stored in pump room. No 3' clearance around all equipment. Ventilation not working in chemical or pump room. Pool built '85. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(b) Provide sufficient lighting in pump room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap.