NamePINEVILLE PLACE
Address12821 MEADOW CREEK LANE
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/31/2019
Final Score @ Grade
24
General CommentsMain drains and skimmer eqaulizer covers expire April 2020. Update drain covers and submit PDSC information for approval prior to expiration to avoid permit action. Unable to verify chlorinator at time of inspection (no flow with pump).

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Weekly total alkalinity and cyanuric acid check missing on records at time of inspection. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and recorded. Corrected.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Skimmer equalizer line blocked/plugged in skimmer at time of inspection. .2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. Operator removed and corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose. Keep tight and in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Some openings in fencing over 4". .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Pool built in 1985.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Lighting fixture not secured to pool wall at time of inspection. .2524(c) Lighting fixtures shall not present a hazard to the public. Operator secured and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some standing water on floor in pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No toilet paper, soap or paper towels in restroom at time of inspection. .2626(j) Provide soap and soap dispenser, no glass, at each sink. .2626(l) Provide toilet paper and dispensers in restrooms. Operator stocked and corrected.