Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePINEVILLE PLACE
Address12821 MEADOW CREEK LANE
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/13/2019
Final Score @ Grade
26
General CommentsPermitted pool. Placed in "A" status. Posted local permit sticker. No Night Swimming permitted. Approved logo with light reflectected value greater than 50% white. (80% LRV). Provided copy of approval to operator. Note: Main drain and skimmer equalizer covers expire April 2020 and must be replaced for 2020 permit.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 7.0 at time of visit. .2535(1) Maintain pH at 7.2 to 7.8. Operator corrected to 7.4.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Pool closed at time of visit, but no cyanuric acid readings or maintenance. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator added maintenance and will start weekly CA readings. Corrected.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets with leaves and debris. Keep clean. Operator cleaned. Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder loose. Keep tightened. .2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fencing bent creating more than 4" gaps between vertical members. Ensure 4" or less is maintained between vertical members. Pool built prior to 2010 (1985), so no permit action taken. Note: If new constrcution is done on fencing and more than 50% is altered thenn fence will no longer be grandfathered in and must meet total compliance of .2528. Contact Environmental Health at 980-314-1620 and apply for any changes/renvations made to pool area PRIOR to work.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Feeder not working properly at time of visit, not shutting off when pump off, but also not feeding. .2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. .2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation. Operator unplugged completely and corrected. There is additional tablet chlorinator in place.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Labeling faded off vaccum line. .2518(d) Piping and valves shall be labeled with color codes or labels.