3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 7.0 at time of visit. .2535(1) Maintain pH at 7.2 to 7.8. Operator corrected to 7.4. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Pool closed at time of visit, but no cyanuric acid readings or maintenance.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator added maintenance and will start weekly CA readings. Corrected. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer baskets with leaves and debris. Keep clean. Operator cleaned. Corrected. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
One ladder loose. Keep tightened. .2521 Install ladders per manufacturer instructions. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Fencing bent creating more than 4" gaps between vertical members. Ensure 4" or less is maintained
between vertical members.
Pool built prior to 2010 (1985), so no permit action taken. Note: If new constrcution is done on fencing and more than 50% is altered thenn fence will no longer be grandfathered in and must meet total compliance of .2528. Contact Environmental Health at 980-314-1620 and apply for any changes/renvations made to pool area PRIOR to work. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Feeder not working properly at time of visit, not shutting off when pump off, but also not feeding.
.2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation.
.2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation.
Operator unplugged completely and corrected. There is additional tablet chlorinator in place. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Labeling faded off vaccum line.
.2518(d) Piping and valves shall be labeled with color codes or labels. |