Water quality: disinfectant residual provided by |
No |
No
|
No |
Pool chlorine at 0 ppm. Maintain pool chlorine through feeder at least 1.0 ppm. Immediate Suspension issued. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No CYA or total alkalinity records for past few months. Ensure weekly record keeping for cyanuric acid and total alkalinity. DPD-2 reagent expired. Replace expired reagent. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One of (2) skimmers without weir. Replace weir.
Water level low. Property trying to lower CYA. Maintain water level at least to skimmer lip so that filtration can occur per mfg. requirements of skimmer. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Body hook not securely attached to 12 ft. pole. Securely attach. Immediate Suspension issued.
Ring buoy rope tangled. Untangled during inspection. Ensure accessible in case of an emergency. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Both doors from club rooms not self-latching. Repair doors to self-close, self-latch. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck popping/offset in multiple locations around pool. Offsets >1/2". Repair decking/coping to ensure no offsets >1/2" and deck slopes to drain. Repair prior to 2027 operating season. Cracked coping at corner on left side of pool. Repair damaged coping.
Hole between deck and coping beside right side step handrail. Repair hole. Hole had been previously repaired but repair no longer in place. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Address and phone number faded off of Kings III phone. Pool sign with address and phone number no longer posted at phone. Corrected during inspection with permanent marker. Ensure visible at all times in case of an emergency. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Pump off. Pump required to be operational at all times pool is open to the public. Turned on during the inspection. Pump shall run between 66 gpm and 95 gpm. Verified at 80 gpm. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Ventilation in chemical storage room not operating. Ventilation shall be continuous in chemical storage room. |