General CommentsPete Pruitt present during the inspection. Intent to Suspend issued for: .2535 - provide cyanuric acid reagent. .2518 - repair leak at multi-port.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No One day missing records in November. Multiple days missing records in October. Ensure daily record keeping for chlorine, pH, temp and main drain checks. No cyanuric acid reagent. CYA used in chlorine tabs. Provide cyanuric acid. Intent to Suspend issued.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Severe etching on pool floor. May require repair in future if worsens. Damage to pool wall under ladder. Repair damage.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose. Tighten ladder. Scum line on ladder handrail. Keep ladders clean/good repair.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Beckets on ring buoy out of place. Moved/corrected during the inspection.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Damage to coping at 4 ft. depth marker. Offset not yet greater than 1/2". May require repair in future if worsens. Damage to grout on left side of pool closest to door. Replace grout. Opening not >1/2".
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Multi-port leaking. Repair multi-port. Intent to Suspend issued. Small leak at pump. Repair leak. Did not warrant permit action at time of inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Floor in pump room wet due to leak at multiport. Keep pump room floor dry.