NameEMBASSY SUITES CHARLOTTE UPTOWN
Address401 E MLK JR BLVD
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/19/2021
Final Score @ Grade
16
General CommentsIntent to Suspend issued for cyanuric acid level and leak at pump. Lower CYA to 100 ppm or less and repair pump. Note: Observed glass tiles in chemical storage room that were used for tiling on pool wall. If ever replaced, do not replace with glass tiles. No glass is permitted in swimming pools. Pool was built after State recommendation on wall tiles. General Comment - Rope on ring buoy starting to fray. Replace with 27 ft. rope within 30 days. Will verify when return visit is made for ITS. Jay Deans present during the inspection. No signature due to covid restrictions.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid used in stabilized tablets. CYA >100 ppm. Maintain at 100 ppm or less. Intent to Suspend issued. Records indicated at 90 ppm. Ensure accurate record keeping.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No End caps missing on ladder rungs. Replace end caps.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some build-up on deck drains. Keep drains free of debris to ensure adequate draining of deck.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No O-Ring on pump leaking. Repair pump so not leaking. Intent to Suspend issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Floor wet in pump room due to leak at pump. Keep pump room floor dry.