5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Cyanuric acid used in stabilized tablets. CYA >100 ppm. Maintain at 100 ppm or less. Intent to Suspend issued. Records indicated at 90 ppm. Ensure accurate record keeping. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
End caps missing on ladder rungs. Replace end caps. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some build-up on deck drains. Keep drains free of debris to ensure adequate draining of deck. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
O-Ring on pump leaking. Repair pump so not leaking. Intent to Suspend issued. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Floor wet in pump room due to leak at pump. Keep pump room floor dry. |