Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
Name808 HAWTHORNE
Address808 HAWTHORNE LN
 
City/State/ZIP
CHARLOTTE NC 28204
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/22/2018
Final Score @ Grade
22
General CommentsCall Chris Sells when pH and ring buoy rope are corrected for reinspection at 704 507 8678.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Observed pH at 6.8. Immediate suspension .2535(1) Maintain pH at 7.2 to 7.8.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed skimmers with debris. Observed 2 skimmers missing weirs. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. .2518(k) Replace missing weirs. Intent to suspend
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed ring buoy rope 2 different pieces. Rope must be 50ft for pool. .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Immediate suspension
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Observed automatic chlorine and acid feeder not turning off when pump is shut off. .2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. Intent to suspend
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed chemicals stored in pump room. Observed pump room unlocked. .2533(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.