Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAQUA-TOTS SWIM SCHOOLS
Address1709 MATTHEWS TOWNSHIP PKY
 
City/State/ZIP
MATTHEWS NC 28105
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/14/2026
Final Score @ Grade
12
General CommentsInspection completed with Kaylee Criscione and Brianna Hernandez present. Intent to suspend permit issued for items listed below. Correct within 30 days or pool permit may be suspended. 1. New heater installed for pool on or around December 2025. EHS could not verify electrical permit information while on site. Provide electrical permitting information or complete electrical inspection if not completed already. 2. Pool heater thermostat is not protected in a way that it is inaccessible to the general public. Ensure the heater thermostat controls are protected from general public by making inaccessible. 3. Trip hazard on pool deck near center column exists. Square black cap cover on pool deck is in poor repair and no longer sufficient to cover opening in pool deck. Repair or replace. Contact Eli Freese with questions at 704.621.2298.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed 2 of 5 total weirs missing. Replace.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2525(b) Heaters shall be equipped with thermostatic controls capable of assuring that the maximum operating temperature of heated public swimming pools other than spas does not exceed 90 degrees Fahrenheit. Such controls shall be accessible only to the operator. Observed heater controls easily accessible to public. Intent to suspend permit issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. Observed pump room unlocked while not in active use.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(i) Water at shower heads shall not exceed 110 F. Observed water coming out of shower at 116F.