Water quality: water temperature of heated pool |
No |
No
|
No |
Observed water to be 92.2F. Heated pool must be 90.0F or less. Pool heater was switched off and water temperature was brought down. -C.D.I. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Observed one return fitting to be missing. Replace the fitting. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed one of the doors to the deck not self-closing/self-latching. All ingress/egress doors onto the deck must be self-closing/self-latching or be alarmed with an audible alarm which sounds upon opening. Correct the door. -I.T.S. Issued, expires 12/13/17. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Observed 911 phone non-functional. Desk phone was set up as 911 phone and verified with 911 services |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed acids and bases stored with containters in contact in the chemcial room. Store them separated to prevent mixing and chemical reaction. |