5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
PH not recorded accurately. Multiple records indicate 7.3 for chlorine, measured 1 ppm on day of inspection. Maintain records accurately.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*Permit item |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Debris in skimmers.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder coming out of pool deck, loose and missing rubber stopper.
.2521 Install ladders per manufacturer instructions. Keep in good repair.
*permit item due to severity |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Holes in pool wall without covers or ropes in place. Keep in good repair and cover opening in wall. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
*permit item |
|
13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
Contrasting color bands on stairs with gaps greater than 1 inch from side of pool. .2521(b) Provide at least 2" painted contrasting color band to edge of stair treads.
.2521(b) Tile shall be no more than one inch from the edge of the tread or adjacent tiles.
*Will allow until 2027 permit for correction. Failure to correct will result in no permit next season. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy rope tangled at time of inspection. Body hook blocked by chairs.
.2530(a) Lifesaving equipment should be conspicuously and conveniently located. Operator untangled rope and moved body hook. Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Leak in equipment room, floor wet, chemicals in equipment room. No clearance around equipment. Lighting not working in equipment room. Pool built 1984.
.2533(b) Provide sufficient lighting in pump room.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(d) Pump room floor shall be kept dry and free of standing water.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |