| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Pool pH not recorded daily. Intent to Suspend issued.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Black algea beginning to grow in pool throughout. No effect on chemistry. Some build-up on tiles inside pool.
.2514(c) Pool finish shall be white or light colored.
.2537(14) Keep pool surface and pool floor free of debris. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One skimmer missing weir. Replace weir. Intent to Suspend issued.
.2518(k) Replace missing weirs. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder handrails loose and one step handrail loose at steps.
.2521 Install ladders per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy rope tangled and not easily accessible.
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
General Comment: Ring buoy grab rope degrading. Replace with USCG approved ring buoy within 30 days. Still usable. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pool gates with meshing/members at 2" by 2 3/4". Distance between vertical members shall not exceed 1.75". Intent to Suspend issued.
Meshing coming off of upper gate. Intent to Suspend issued.
.2528(4) Where barrier is composed of horizontal and vertical members andthe distance between horizontals is less than 45", spacing between the verticale members shall not exceed 1.75".
Pool built pre-2010. Pool fence <48" in some locations due to vegetation. <45" between horizontals on pool fence and >2" under gates.
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
.2528(a) Maintain 2" or less under fence and/or gate (post-May 2010).
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pool furniture <6 ft. from pool by steps.
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
Minor deck drain damage near safety equipment. Continue to monitor and repair as needed.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Facility provided warning signage not 4". Warning No Lifeguard on Duty signage in 4" lettering provided during inspection.
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Pool lights not verified. Could not be turned on. Pool is currently approved for night swimming. Lights must be operational for night swimming approval. Either repair lighting or change hours. Intent to Suspend issued. Night swimming is disapproved until lights are corrected.
.2524(a) Pools that are to be used at night shall have sufficient artificial lighting provided. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Sand filter leaking. Does not appear to affect pool chemistry.
.2518 Maintain pool equipment in good repair. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Men's restroom without toilet paper and one toilet soiled with gnats present.
.2626(l) Provide toilet paper and dispensers in restrooms.
.2626(m) Keep restrooms and fixtures clean and in good repair.
Hot water in restrooms at 115 F.
.2626(i) Water in restrooms shall not exceed 110 F. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No hose bib in pump room.
.2626(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. |