| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Pool chlorine at 0 ppm. Liquid chlorine used and present. Automated chlorinator used. Assure chlorine at least 1.0 ppm in pool. Chlorinate through chlorinator. Immediate Suspension issued. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH at 7.0. Automated system indicates 7.34. Assure pool pH maintained at 7.2 to 7.8. Immediate Suspension issued. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No main drain checks recorded. Record daily. Records indicate chlorine at 3.0 ppm for last couple weeks. Assure accurate record keeping. Operator indicated they were using test strips to test chemicals. Recommend using a liquid test kit for testing of pool chemicals at least daily. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some build-up on pool wall depth marker tiles. Keep clean. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One skimmer at far end by emergency phone with no suction. Repair skimmer to provide adequate suction to swimming pool.
Skimmer lid cracked. Replace lid. Keep in good repair. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
One handrail at steps loose. Keep in good repair. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
One gate not self-closing. Repair to self-close.
One gate with meshing not in place. Allows for less than 45" between horizontals.
Observed <45" between horizontals on fence. Pool built prior to 2010. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed pool furniture less than 6 ft from pool edge. Corrected during inspection.
Deck damage in some locations. Offsets less than 1/2". Monitor to ensure no offsets or protrusions greater than 1/2".
Deck damage where deck is missing >1/2" decking near 5 ft. Repair to eliminate hazard. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Chlorinator could not be verified. Automated chlorinator and acid feeder. Feeder must detect flow and turn off when pump turned off. Will verify on return visit. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored on pump room floor. Store all chemicals in chemical storage room. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Labeling wearing off on piping in pump room. Clearly identify all pipes with color codes or labels. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restrooms >115 F. Maintain at 110 F or below. No soap in men's restroom. Provide soap. 4 stalls in women's restroom without toilet paper. Provide toilet paper. |