5
|
0
|
Procedures for responding to vomiting & diarrheal events |
Yes |
No
|
No |
2-501.11 A food establishment shall have written procedures for employees to follow when responding to vomiting or diarrheal events. -Pf For more information please visit: http://meck.co/FoodSafety No written policy in place at establishment regarding the cleanup of vomit/diarrheal events. CDI - Establishment e-mailed sample policy. 0 pts. |
|
22
|
1.50
|
Proper cold holding temperatures |
No |
No
|
Yes |
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P - Cartons of milk and half and half measured 44-45F in front reach-in cooler. Reach-in cooler air temperature was 50F. TCS foods must be held at 41F or less in cold holding. Half and half and milk cartons moved to walk-in cooler to cool down and will be moved to another front reach-in cooler that was functioning at the correct temperature until the first cooler can be repaired. VR - Verification required within 3 days that the cooler has been repaired. |
|
44
|
0
|
Utensils, equipment & linens: properly stored, dried & handled |
Yes |
No
|
No |
4-903.11 (A) Store cleaned equipment, utensils, linens in a clean, dry location; where they are not exposed to splash, dust, or other contamination; and at least 6 inches above the floor. Bag of clean towels stored on shelf below chemicals. Do not store chemicals above clean linen. CDI - Linen moved to top of shelf by manager. 0 pts. |
|
48
|
0.50
|
Warewashing facilities: installed, maintained & used; test strips |
No |
No
|
No |
4-603.15 (A) - (C ) Follow required alternative manual warewashing procedures for fixed equipment and large utensils. Manager states that milkshake wand is cleaned every 4 hours with sanitizer solution. Ensure milk shake wand is washed with detergent/soap, rinsed with clean water, and then sanitized with a sanitizer solution at the appropriate concentration. |
|
51
|
0
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-205.15 Maintain a plumbing system in good repair. 3-compartment sink stoppers are not functioning. Plumbing fixtures shall be maintained in good repair. 0 pts. |