11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder extends > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
Some steps loose on ladder. .2521 Install ladders per manufacturer instructions. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence with sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Gate by emergency phone not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan not functioning in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |