NameGRAYSON APARTMENTS, THE
Address6001 BENNETTSVILLE LN
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/12/2021
Final Score @ Grade
22
General CommentsInspection conducted with Mike Tanski. Due to COVID-19 Precautions, inspection not signed by the operator. Looks like the underwater light is not fully installed. Ensure light is fully installed in the light niche. No label observed on pool pump. Motor is labeled as being a Pentair Challenger CHII-NI-3FE pump motor. Immediate suspension issued 15) 22) Contact Will Harrison (704-507-6824) when items have been corrected for a re-inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy damaged with 64 foot rope attached. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope. - Immediate suspension item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence with sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pre-2010 fence with gaps > 4" under the fence. 2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
22 6 Premises: emergency telephone provided No No No Emergency phone not functioning. .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. - Immediate suspension item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Observed 2" flow meter installed on 3" return line. .2518(g) Install a functioning flow meter on return line per manufacturer instructions. - Intent to suspend item.