11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder extends > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy damaged with 64 foot rope attached. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope. - Immediate suspension item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence with sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Pre-2010 fence with gaps > 4" under the fence. 2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not functioning. .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. - Immediate suspension item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Observed 2" flow meter installed on 3" return line. .2518(g) Install a functioning flow meter on return line per manufacturer instructions. - Intent to suspend item. |