Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameGRAYSON APARTMENTS, THE
Address6001 BENNETTSVILLE LN
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/30/2018
Final Score @ Grade
18
General CommentsNO POINTS WERE TAKEN FOR THE FOLLOWING: #25 - Observed hose bib on shower without backflow prevention device. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Observed no ventilation in pump room or chemical storage room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. PDSC Information verified. Night swimming is not approved until return visit is made to see that there is sufficient lighting.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No REPEAT Observed pool ladders missing rubber bumpers. Operator showed EHS ladder bumpers and stated they will be installed tomorrow. Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No REPEAT Observed rope for ring buoy to be 55 feet when 50 feet is required. CDI: Operator shortened rope to 55 feet during inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed one gate and door to fitness center to be self-closing but not quite self-latching. CDI: extra spring was added to gate and door was adjusted so that both are now self-closing and self-latching. .2537(b) All gates and doors shall be self-closing, self-latching.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed no extra pump basket onsite. CDI: Operator ordered pump basket and showed EHS confirmation during inspection. .2518(e) Provide a spare basket for pump.
27 2 Equipment room: filter backwash discharged through an air gap No No No REPEAT Observed no air gap for backwash pipe. .2513(b) Filter backwash shall be discharged through an air gap.