Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMAGNOLIA TERRACE APARTMENT HOMES
Address8301 PACES OAKS BLVD
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/11/2023
Final Score @ Grade
24
General CommentsIssued immediate suspension for ring buoy and throw rope as well as inoperable emergency phone. Please call James Bjorneboe at 704-507-6820 once items are corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed 1 of 4 weirs missing. Replace missing weirs. .2518(k) Replace missing weirs.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed both ladders missing endcaps. Replace missing end caps. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed ring buoy in extremely poor condition. Replace with USCG approved buoy with 38’ throw rope attached. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed two gates on left side of pool not self-closing/ self-latching. Ensure gates are self closing/ self latching. .2537(b) All gates and doors shall be self-closing, self-latching.
22 6 Premises: emergency telephone provided No No No Emergency phone inoperable. Repair. .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap provided ad back wash pit. Provide air gap. .2513(b) Filter backwash shall be discharged through an air gap.