Premises Information

Return to Inspections
NameMAGNOLIA TERRACE APARTMENT HOMES
Address8301 PACES OAKS BLVD
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/28/2021
Final Score @ Grade
36
General CommentsInspection conducted with CPO Orlando Maldonado and property manager Lynn Kerr. Due to COVID-19 precautions, inspection was not signed by the CPO. Note: pH < 6.8. Recommend having Carribean Pool Services recalibrate the automatic chemical feeders. Immediate suspension issued 3) 6) 22) Call Will Harrison (704-507-6824) to schedule reinspection when ready.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No Main Drain Checks. Check daily Cl, pH, main drains, and record pool maintenance activities. Check at least weekly Total Alkalinity and Cyanuric Acid. Maintain Cyanuric Acid at no more than 100 ppm. - Intent to suspend item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Observed 8HP equalizer line covers installed. Covers expire 5-3-2021. PDSC form states that equalizer lines were abandoned. Either abandon equalizer lines per state guidance or replace with APSP-16 approved covers and provide updated PDSC form to our office. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Immediate suspension item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladders extend > 6" into the pool. .2521 Install ladders per manufacturer instructions. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate by office not self-closing. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some deck chairs too close to pool edge. Maintain at least 6 feet clear walkway around the pool. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Immediate suspension item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room being used for general storage. Some items stored near pool equipment or chemicals. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash line extends into backwash pit. .2513(b) Filter backwash shall be discharged through an air gap.