| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
New main drains installed when pool was replastered. Appear to be Waterway 640-231x covers. These covers are not rated to handle the maximum speed of the CHII-NI-3FE pump installed. .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Immediate suspension item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Missing one weir. .2518(k) Replace missing weirs. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Depth markers in the shallow area should all be 3 1/2 feet, some on wall or deck are 3 feet. .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. Ensure depth markers on deck are slip resistant. - Intent to suspend item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladders missing endcaps, extend > 6" into the pool. .2521 Install ladders per manufacturer instructions. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One inlet fitting missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
Fitting missing for fill line. Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gate to playground not self-closing. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Immediate suspension item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Vacuum cap missing for vacuum line by the main drains. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Leak at the filter. .2533(d) Pump room floor shall be kept dry and free of standing water. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash line extends into backwash pit. .2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Faucet in men's and women's room loose. .2526(m) Keep restrooms and fixtures clean and in good repair. |