3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH 6.8 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Operator corrected to 7.6. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored outside with no coverage. Original construction. Chemicals shall be stored in a weatherproof structure.
.2534(1) Chemical storage room shall be weatherproof with a minimum ceiling height of 7 ft. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
No backflow prevention on hose bib at time of inspection. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.
Operator added anti siphon valve to hose. Corrected. |