Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCAROWINDS - KIDDY HAWK COVE - SYS B
Address14523 CAROWINDS BLVD
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type56 - Seasonal Specialized Water Recreation
CountyMecklenburg
Inspection Date 5/18/2021
Final Score @ Grade
26
General CommentsHayward SP2607x10 pump for chlorinator. JJ Sexton present during the inspection. Inspection conducted with Marie Daley and Katie Rudisill. Permit issued for no night swimming. Sticker provided. State permit will be posted online within 2 - 3 business days.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Rusted screw on one inlet. Replace screw/fitting. Some rust on main play structure. Does not appear to be a cut hazard. Continue to monitor and repair if needed. Keep all equipment in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No >6" under back gate near pump room. Gravel added during inspection and corrected to <4".
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some cracking on pool deck. Continue to monitor and repair as needed. Deck furniture <4 ft. to pool edge. Maintain 4 ft. clearance around pool.
22 6 Premises: emergency telephone provided No No No One phone not ringing back. Corrected during the inspection.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Backwash pit leaking. Reseal tank so it does not leak.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet due to leak at backwash tank. Keep dry. Light in storage room for acid not operable. Providing lighting in chemical storage rooms.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Sinks and toilets with build-up in restrooms. No soap at some sinks in men's restrooms. Keep all fixtures clean and in good repair.