2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
1ppm free chlorine observed. .2543(7) Interactive play features shall maintain chlorine at least 2.0 ppm. - Pre-permit item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No recent total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Corrected. Operator did a test today. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Automatic feeder in pump room does not turn off when the pump is off. .2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. - Pre-permit item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Automatic feeders in vault no longer functioning, operator must hand feed chlorine and acid. .2543(d)(6) Automatic chemical controllers shall be provided to monitor and adjust the disinfectant residual and pH of the water contained in the system. - Pre-permit item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored on a cart in a general storage area. Ensure chemicals are only stored in an area designed to store chemicals safely and away from non-chemical items. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |