Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCAROWINDS - TIDAL WAVE BAY - SYS BB
Address14523 CAROWINDS BLVD
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type56 - Seasonal Specialized Water Recreation
CountyMecklenburg
Inspection Date 6/24/2021
Final Score @ Grade
20
General Comments16 - Door on backside of women's restroom with cardboard in door to prevent it from self-latching. Removed during the inspection. Doors shall remain self-closing, self-latching. 22 - Emergency phone located at left side of wave pool with emergency response hard to hear. Pushed line into phone and addressed low tone. Monitor and replace if worsens. 26 - Recommend labeling the bubbler return. Permit issued for no night swimming. State permit provided. Sticker will be mailed. Inspection completed with JJ Sexton. No signature due to covid restrictions.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some goose droppings zero entry area in swimming pool. Keep pool free of build-up.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Damage to no diving marker on left side of pool, near 6 ft. at end of pool. Replace by 2022 operating season. Public does not have access to area.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some cracking on pool deck and damage to deck - right side tie into wall. Continue to monitor and repair as needed.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Some minor leaks on piping at filters. Repair as needed.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet. Appears to be coming through the side walls. Keep pump room floor dry.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One sink in women's restroom not operable. Keep fixtures operable.