Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameUS NATIONAL WHITEWATER CENTER
Address5000 WHITEWATER CENTER PARKWAY
 
City/State/ZIP
CHARLOTTE NC 28214
Premise Type57 - Year Round Specialized Water Recreation
CountyMecklenburg
Inspection Date 8/10/2022
Final Score @ Grade
22
General CommentsRoss Thomas present during the inspection. Immediate Suspension issued for emergency phone. Once corrected, contact Katie to schedule a return visit to re-open the pool. Pool shall remain closed until a return visit is made. Pool Closed signs posted during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some algae build-up on walls in multiple locations and also inside skimmer lips. Treat as needed. Operator is aware and has been addressing the issue. Some debris on pool floor. Keep pool floor clean. Some pool lights with small gaps from wall to light. <1/2". Monitor and repair to ensure no gaps >1/2" between light niche and wall.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No One wall depth marker at 16 ft. 6 in. with 6 in inches faded. Still visible. Monitor and replace if worsens.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some build-up/algae growth under shower on deck. Eliminate to ensure decking is maintained as slip-resistant.
22 6 Premises: emergency telephone provided No No No Emergency phone number posted not listed with 911. Phone number listed goes to automated service of USNWC. When number posted dialed, it rings back to the emergency phone. Phone number posted and listed with 911 shall match signage and audibly ring back to the emergency phone on the pool deck. Immediate Suspension issued.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One toilet leaking in women's restroom. Repair. Keep fixtures in good repair.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Flooring in restrooms with sealant worn off. Floor does not appear to be slip-resistant. Reseal prior to 2023 operating season for permit.