2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Pool chlorine at 1.5 ppm. Required at 2.0 ppm. Corrected during inspection. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some minor debris on pool floor and some build-up on pool wall on shallow side. Keep pool clean and in good repair. Build-up did not affect clarity. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One skimmer plugged and without basket near pump room. Leak in skimmer. Pool will keep plugged until leak repaired. Assure basket in place when operating. 24 skimmers required for swimming pool. Pool has 26 skimmers. Temporarily approved with 25 skimmers until repair made unless clarity or ciruculation issues arise. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Two returns plugged due to leak. Pool required 130 returns. Pool plumbed with 130 returns. Returns must remain operational. Intent to Suspend issued. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some standing on water on pool deck where deck is no longer sloped to drain. Keep pool deck free of standing water. Monitor as to not become a hazard to the public.
Drill hole in pool deck near pump room where repairs have been made. Repair hole. No offsets or openings in pool deck >1/2". Intent to Suspend issued. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Lights were not operational at time of inspection. Night swimming approved. Repaired during inspection. Observed one light burnt out for overhead lighting. Sufficient lighting provided with remainder of lighting. Repair light. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Observed hose bibs in pump room and some surrounding pool deck without backflow prevention device. Provide backflow prevention device on all hose bibs. |