Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameUS NATIONAL WHITEWATER CENTER
Address5000 WHITEWATER CENTER PARKWAY
 
City/State/ZIP
CHARLOTTE NC 28214
Premise Type57 - Year Round Specialized Water Recreation
CountyMecklenburg
Inspection Date 7/27/2018
Final Score @ Grade
28
General Comments5 - General Comment - Observed cyanuric acid recorded at 16 ppm and lower levels. Recorded reading of 50 ppm during site visit. General Comment - Ring buoy grab ropes starting to degrade. Replace ring buoy and ropes with USCG approved and 50 ft rope if to remain on deck. Will verify on return visit for intent to suspend items. Intent to Suspend issued for returns (remain operational) and for drill opening in deck >1/2".

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Pool chlorine at 1.5 ppm. Required at 2.0 ppm. Corrected during inspection.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some minor debris on pool floor and some build-up on pool wall on shallow side. Keep pool clean and in good repair. Build-up did not affect clarity.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer plugged and without basket near pump room. Leak in skimmer. Pool will keep plugged until leak repaired. Assure basket in place when operating. 24 skimmers required for swimming pool. Pool has 26 skimmers. Temporarily approved with 25 skimmers until repair made unless clarity or ciruculation issues arise.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Two returns plugged due to leak. Pool required 130 returns. Pool plumbed with 130 returns. Returns must remain operational. Intent to Suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some standing on water on pool deck where deck is no longer sloped to drain. Keep pool deck free of standing water. Monitor as to not become a hazard to the public. Drill hole in pool deck near pump room where repairs have been made. Repair hole. No offsets or openings in pool deck >1/2". Intent to Suspend issued.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Lights were not operational at time of inspection. Night swimming approved. Repaired during inspection. Observed one light burnt out for overhead lighting. Sufficient lighting provided with remainder of lighting. Repair light.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Observed hose bibs in pump room and some surrounding pool deck without backflow prevention device. Provide backflow prevention device on all hose bibs.