Premises Information

Return to Inspections
NameUS NATIONAL WHITEWATER CENTER
Address5000 WHITEWATER CENTER PARKWAY
 
City/State/ZIP
CHARLOTTE NC 28214
Premise Type57 - Year Round Specialized Water Recreation
CountyMecklenburg
Inspection Date 8/1/2017
Final Score @ Grade
30
General Comments21 - General Comment - Lights could not be veriifed. For night swimming, pool lights must be operational. Will verify on return visit. Operator indicated that during off season sumps will be changed out for stainless steel. If construction done to plumbing during off season, the Health Department shall be contacted and an onsite visit to verify plumbing is required. Intent to Suspend issued for gate and chemical feeder.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No One day missing from log book for main drain checks. Assure recorded daily. Logs are kept in separate location and must remain accessible at all times.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some debris on pool floor. Keep clean.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer missing weir and one skimmer on skimmer lip under lid at 20 ft depth near pump room. Replace weir and keep skimmers in good repair.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder loose. Tighten to maintain good repair.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Some returns missing fittings. Replace where needed.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One gate not self-latching, self-closing. Repair to self-latch, self-close. Intent to Suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some damage to caulking around skimmer lid at 16 1/2 ft. Repair caulking where needed.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Pool has switched to liquid chlorine with new chlorine feeder pumps. Could not verify that feeder pumps turn off when pumps turn off. Intent to Suspend issued. Operator shall demonstrate that feeders do not continuously run after filtration pumps turn off.