30
General Comments15 - Rusted screws on body hooks/poles. Replace screws within 30 days. Will verify on return visit for Intent to Suspend. Intent to Suspend issued for: .2537 - clean algae on platform and steps. .2528 - repair men's door to self-close, self-latch. Daniel Osucha and Tell Bumgarner present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Severe etching on the pool floor and some damage near the basketball hoop by the door. Pool will require repair if worsens to a hazard. Discoloration of pool floor does not appear to be >50% light reflectance. Pool floor shall reflect >50% light. Debris on drains and some areas with debris/sand. Ensure pool is cleaned regularly to keep pool floor clean. Some rust around mud ring of left drain at waterslide. Ensure pool floor is kept clean.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Gutter grates slightly loose/popping at corner of pool near basketball hoop where deck is popping. Secure grates. Offset not greater than 1/2" at time of inspection.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder handrail at lazy river loose on right side. Tighten/secure ladder in cup.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Scum line on feature handrails for steps. Ensure fittings kept in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Men's restroom door not latching. Repair door to self-close, self-latch. Intent to Suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No - Decking near basketball hoop and double doors "popping". Offset now at 1/2". Requires repair prior to 2027 operating season. Deck repair shall slope to drain and be slip resistant. - Cracking at tile and decking near 0 ft. entry point. Opening/crack in tile not greater than 1/2" at time of inspection and did not present hazard to the public. - Some areas where deck tile is missing or grout areas damaged. Repair where needed. - Algae build-up on platform and steps leading into waterslide. Keep decking free of slip hazards. Intent to Suspend issued. - Rafts located within 5 ft. clearance of pool deck. Maintain 5 ft. clearance around the pool in all locations.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Small leak at gasket to filtration pump. Repair leak.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor where pumps kept wet due to leak at filtration pump. Keep dry. HVAC chemical kept in pump room. Ensure pool chemicals stored in chemical storage room. No chemicals, due to ventilation rating, stored in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms at 114 F. Maintain at 110 F or below. Handicap sink slow draining in women's restroom. Keep fixtures in good repair. Note: Men's restroom not viewed. Could not access.