NameRAYS SPLASH PLANET
Address215 N. SYCAMORE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type57 - Year Round Specialized Water Recreation
CountyMecklenburg
Inspection Date 3/20/2025
Final Score @ Grade
32
General Comments26 - Ensure all piping is labeled so clearly visible. Third pump, could not identify while in lower pump room. Daniel Osucha present during the inspection. Intent to Suspend issued for the following: .2523 - replace depth markers where needed at 3 1/2 ft .2537 - clean floor at steps and walkway to slide exit - eliminate algae .2528 - repair double doors to self-close, self-latch Screws for Paddock drain covers last changed on 9/19/2019. Due for change in 2026.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some debris on pool floor at slide plunge area and on main drain covers. Severe etching in some areas on the pool floor. May require repair in future if worsens.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No 3 1/2 ft. depth markers on pool wall at vortex and on peninsula of lazy river either missing or peeling off. Intent to Suspend issued.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose in lazy river. Tighten and maintain secure.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Some build-up and rust on white steps on play feature. Keep all fixtures clean and in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Double doors not self, close. Repair both doors to self-close, self-latch. Intent to suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Less than 5 ft. from pool wall to edge of pool due to floats on the side of the pool at the lazy river. Maintain 5 ft. clearance around the pool. Step and standing area for the slide with algae. Keep area free of algae to eliminate slip hazard. Intent to Suspend issued. Tile missing from coping near far end basketball hoop and at lazy river. Replace tiles where needed. Standing water on peninsula between play structure and lazy river. Public does not have access. Deck shall slope to drain with no standing water.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Small leak at F13 and pipe for feature. Repair leak. Leak not severe enough to warrant an ITS.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Floor wet in pump room due to leak. Keep floor dry.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One soap dispenser not operable in women's locker room. Keep fixtures in good repair.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Floor in blue family restroom holding water. Recommend providing SOP for keeping floor free of standing water.