Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRAYS SPLASH PLANET
Address215 N. SYCAMORE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type57 - Year Round Specialized Water Recreation
CountyMecklenburg
Inspection Date 2/7/2023
Final Score @ Grade
20
General CommentsDaniel Osucha present during the inspection. 6 - General Comment - One screw missing from left drain covers near bball hoop. All other screws in place. Drains seem secure and recently inspected 2/2023. Chlorinator verified to detect flow during the inspection. Intent to Suspend issued for the following: .2528 - repair double doors to self-close, self-latch .2523/.2537 - replace depth markers as listed in the inspection .2537 - repair chipped plaster on pool floor near slide

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some sand along pool floor specifically in slide area. Keep pool floor clean. Repeat - Some etching on pool floor throughout. May require repair in future if worsens. Chipping plaster at slide area. Repair chipped plaster to eliminate hazard. Intent to Suspend issued.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Wall and deck depth markers peeling back in multiple locations. Area required for repair: - 3 1/2 ft. by step exit slide area on deck. - 3 1/2 ft. on wall by rope at slide area. - 3 1/2 ft. on deck near vortex. Replace in any other areas that worsen. Intent to Suspend issued.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Repeat - Ladder at lazy river loose. Tighten handrails.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Double doors to exterior not self-closing, self-latching. Intent to suspend issued. Repair to self-close, self-latch.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Two tiles missing at zero entry. Offset not greater than 1/2".
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water >113 F in restrooms. One sink faucet not operable at family restroom closest to pool entry. Repair faucet.