Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameRAYS SPLASH PLANET
Address215 N. SYCAMORE ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type57 - Year Round Specialized Water Recreation
CountyMecklenburg
Inspection Date 11/30/2021
Final Score @ Grade
12
General Comments6 - Working with operator on VGB paperwork. Verified pool pumps and drain covers during site visit. Operator provided plumbing drawing which shows that filtration pumps and feature pump are tied to surge tank. Vortex pump and slide pump are tied to trench drain and drains in front of slide. All pumps are tied to trench drain. Assume that all drains are getting suction from all pumps. Max flow of all pumps at 9150 gpm. (7) Paddock 2040PCGO at 1960 gpm. With one drain covered, max flow of pumps does not exceed drain covers at 11,760 gpm total. Waiting on final paperwork from operator. Given to end of 2021 to provide. 16 - Audible alarms placed on doors as temporary repair. If removed, doors shall self-close, self-latch. Currently all doors either self-close, self-latch or self-close with audible alarm. Note: Repair made to leak at surge tank. No longer leaking. Permit issued for night swimming. Danial Osucha present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some etching on pool floor and debris on pool floor. Keep pool floor clean and in good repair.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some damage to tile near lifeguard chair at vortex. Keep pool deck in good repair. Area is not used by public.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Handicap rail in restroom in women's pulled from wall. Repair rail to wall. Keep fixtures in good repair. Two hand drying devices not operable in men's and women's. Keep all fixtures operable.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Damage to floor near shower with flooring cracking in men's restroom. Keep flooring in good repair.