5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Test kit with expired reagents or test tubes with build-up. Replace test kit. Intent to Suspend issued.
.2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity.
Paddock drain covers installed. January 2020 requires recertification of drain covers, per Paddock requirements. Provide certification. Intent to Suspend issued. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Repeat Item - No wall depth marker at stair entry to slide area. 3 1/2 ft. on deck. >25 ft. between depth markers. Provide at end of step area at 3 1/2 ft at wall. To left of stair. Intent to Suspend issued.
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool.
Some depth markers on pool wall (2 ft. at vball net area and 3 1/2 ft at lazy river) beginning to peel off. Continue to monitor as need.
.2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Standing water on pool deck near steps for slide and also around clean-out near zero entry.
.2522(f) Deck shall be sloped to drain. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Operator not present at time of inspection. Chlorinator and acid feeder not verified at time of inspection. Ensure automated systems detect flow and turn off when pump turns off. Intent to Suspend issued.
.2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Container of chemical stored in pump room. Store in approved chemical storage space.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restrooms >115 F. Maintain at 110 F or below. Repeat item.
.2526(i) Water in restrooms shall not exceed 110 F. |