Inspection Date 5/16/2023
Final Score @ Grade
20
General CommentsPermit denial for emergency phone and caulking/deck in good repair. “Q” status Call 980-314-1620 to pay $100 revisit fee, ID 560001 then schedule re-inspection with Marie Daley at 704-507-6806 when in compliance for permitting (currently set to Wed 5/24 at 8:30 a.m.) Inspection with JJ Sexton, Hope McIntosh and Marie Daley

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing weekly alkalinty checks, but have just started being kept. Will check on return visit. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some debris on lazy river floor. Keep clean. Some cracking on plaster on steps at zero entry. Monitor and repair if worsens. Plaster does not appear to be >50% light reflectance at zero entry and steps. If plaster is replaced, must reflect >50% light.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Decking around pool with multiple locations with damage and caulk causing offsets greater than 1/2”. Damage to coping/deck tie in around back side across from bamboo area with damage that required repair for 2023 season. Some of decking has been repaired, but not completely on walking side of lazy river. *Permit item .2537(2) Decks shall be kept in good repair.
22 6 Premises: emergency telephone provided No No No Emergency phone not operable on back side of lazy river. .2530(f) Emergency phone shall remain operable. *Permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Liquid chemicals stored outside. Original construction. .2534(1) Chemical storage room shall be weatherproof with a minimum ceiling height of 7 ft.