Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAPARTMENTS AT HOLLY CREST - INDOOR SPA
Address16312 HOLLY CREST LN
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 1/13/2026
Final Score @ Grade
42
General CommentsInspection conducted with CPO Juan Trujillo. Spa open for use, facility out of bromine. No bromine in the spa. Any time the water chemistry is off will need to keep the spa closed until the water chemistry is properly balanced. Paramount SDX2 main drains on spa floor expire 7-7-2026 and Aquastar A10RCFR main drains on spa wall expire 7-2-2028. Prior to expiration, replace with new APSP-16 approved covers and submit updated PDSC form to our office for approval. Not able to check that automatic acid feeder shuts off when the pump is off, has been kept off until the shipment of bromine comes in. Will check on return visit. Not able to check spa timer. When timer was activated, water from spa jet pump flowed back through air inlet pipe and flooded the pump room. Will check on return visit. Immediate suspension issued 2) 3) 4) Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No No free bromine in the spa. .2535(5) Maintain bromine at least 2.0 ppm. - Immediate suspension item.
3 6 Water quality: pool water pH No No No pH > 8.4. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
4 6 Water quality: water temperature of heated pool No No No Spa heater has been running high last few inspections. Observed water temperature at 108.6F today. .2535(12) Maintain spa temperature at 104 F or below. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No records since September. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for total alkalinity. - Intent to suspend item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some sand on the spa floor. This is a recurring item. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Water an inch below the gutter. .2518(k) Water level shall be maintained above the level of the overflow trough on gutter. - Intent to suspend item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Self-closer on door to fitness center has been removed. Door not self-closing. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Both mini splits not functioning. Does not appear that primary ventilation system is working either. .2524(f) Indoor pools shall have mechanical ventilation. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not observed in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Pump room floods when using spa jets. .2533(d) Pump room floor shall be kept dry and free of standing water. Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Items stored by spa piping. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Soap dispenser damaged in men’s restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.