Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAPARTMENTS AT HOLLY CREST - INDOOR SPA
Address16312 HOLLY CREST LN
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 12/8/2020
Final Score @ Grade
30
General CommentsLori Greer present during the inspection. No signature due to covid restrictions. Immediate Suspension issued for chlorine levels. Maintain at least 1.0 ppm. Once corrected, contact Katie Rudisill at 704-309-5494 to schedule a return visit to reopen your spa. Note: Pool main drains expire in July 2021. Drains shall be changed out by July 2021 with a new PDSC form for approval.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Spa chlorine at 0.2 ppm. Automated feeder that continuously is pumping chlorine into the spa with no chlorine in spa. Chlorine switched to tab feeder at time of inspection until feeder can be repaired but no change in chlorine. Ensure chlorine at least 1.0 ppm through feeder. Do not shock or handfeed the spa to increase chlorine.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid above 100 ppm. Lower to below 100 ppm. Change of CPO on staff. Lori Greer now CPO. Provide CPO information.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some sand on spa floor and etching on benches, spa floor. Keep spa clean. Maintain walls/floors in good repair. Continue to monitor etching and repair if worsens to become a public hazard.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Spa light not operable. Spa approved for night swimming. Repair light.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Liquid chlorine and acid feeder. Feeder not operating correctly and continuously running. Repair feeder. Could not verify if feeder detects flow due to feeder not working properly. Operator shall be capable of showing verification of flow - feeder detects flow and turns off when no flow.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Repair so operable.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Water on floor under spa jet pump due to small leak around gasket. Repair leak and maintain dry floors in pump room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Jet pump piping not labeled. Clearly identify all piping with color codes or labels.