Inspection Date 7/2/2025
Final Score @ Grade
24
General CommentsInspection conducted with CPO Killian. Permit may be issued and pool may open. Submit updated PDSC to the health department when ready to unplug the equalizers. See notes below. Const. Date: 7/1/1982 Rope Length: 30' No night swimming Verified the following during the inspection: Flow meter must remain operable. Flow required at least 105 gpm to 141 gpm to meet turnover and flow restriction of the filter. Flow shall not exceed 150 gpm due to drain cover flow restriction. Suction Hazard. VERIFIED 120GPM New Pump Pentair Intelliflo3 VSF 011077, 3 hp pump VERIFIED Blue white flow meter reading the above permit restriction. REMOVED AND REPLACED Main drain, skimmer and return line all 3” line coming out of the pump room floor. VERIFIED (2) Aquastar 1216xxx 2017 drain covers. VERIFIED (1) Pentair TR140C filter VERIFIED 10 returns VERIFIED 6 FLOOR 4 WALL 4 skimmers with EQ lines plugged per State requirement. EQUALIZERS HAD BEEN UNPLUGGED AND NEW SDX2 RETRO INSTALLED - INFORMATION NOT APPROVED OR REFLECTED ON THE PDSC. OPERATOR PLUGGED EQUALIZERS TO OPEN POOL UNTIL NEW EQUALIZERS ARE APPROVED. NO SUCTION HAZARD WHILE PLUGGED.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Equalizers covers installed without documentation from PDSC. Operator re plugged equalizers on the inside and outside to maintain suction safety until new equalizer covers can be approved by Health Department. No permit action.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope for ring buoy greater than 30’. Corrected during inspection. No permit action.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Maintain horizontals no less than 45" in height. Pool built '92, no permit action.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Items within 3' of piping. Pool built '92. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. Pool built 1992. .2513(b) Filter backwash shall be discharged through an air gap
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2526(h) Shower(s) shall be provided. Shower not provided
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No floor drains in restroom. No hose bib in restroom within 50’ Pool built ‘92. .2526(c) Floor drains shall be provided in restrooms. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.