9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Depth markers at various areas of pool deck and on sides of pool at coping with some cracking. Operator noted they are planning on re-decking and re-surfacing pool spring 2024. Repair or replace cracked depth markers prior to permit issuance in 2024. No permit action at this time. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope for ring buoy greater than 30’. Corrected during inspection |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Gaps under fencing greater than 4" in some areas on hill. Maintain horizontals no less than 45" in height. Pool built '92, no permit action. Ensure windows onto pool deck do not open greater than 4" (unable to verify).
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Items within 3' of piping. Pool built '92.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Labels fading piping .2518(d) Piping and valves shall be labeled with color codes or labels. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash. Pool built 1992. .2513(b) Filter backwash shall be discharged through an air gap |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No floor drains in restroom. No hose bib in restroom within 50’ Pool built ‘92. .2526(c) Floor drains shall be provided in restrooms.
.2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. |