16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Gaps under fencing greater than 4" in some areas on hill. Maintain horizontals no less than 45" in height. Pool built '92, no permit action. Ensure windows onto pool deck do not open greater than 4" (unable to verify).
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
*Note: Discussed removing plex-glass from gates. Plexi-glass is on gates because of horizontal (metal pice on side) less than 45” in height. Gate latches are all at least 54” in height. Gate is at least 48” in height, top horizontal is 45”. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Coping/bricks loose and coming out around pool at 4 FT depth marker. Deck cracking in back right corner, maintain less than 1/2" offset. Operator filled with caulk. Corrected. Advised monitoring deck for repairs.
Chair within 5' of handrail. Operator moved and corrected.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
.2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Items within 3' of piping. Pool built '92.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Labels fading piping .2518(d) Piping and valves shall be labeled with color codes or labels. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash. Pool built 1992. .2513(b) Filter backwash shall be discharged through an air gap |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No floor drains in restroom. No hose bib in restroom within 50’ Pool built ‘92. .2526(c) Floor drains shall be provided in restrooms.
.2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. |