Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameWILDWOOD APARTMENTS
Address1022 FOREST OAK DRIVE
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/25/2022
Final Score @ Grade
16
General CommentsIssued local permit sticker. Verified PDSC information: Pentair Challenger CHII-NI-3F, 3 HP (missing placard on pump, unchanged) 2 Aquastar 1216 (VGBA 2017), 4 Paramount SDX 2 skimmer equalizer covers Contrasting color bands have been corrected No Night Swimming “A” Open for Business

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Gaps under fencing greater than 4" in some areas on hill. Maintain horizontals no less than 45" in height. Pool built '92, no permit action. Ensure windows onto pool deck do not open greater than 4" (unable to verify). .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). *Note: Discussed removing plex-glass from gates. Plexi-glass is on gates because of horizontal (metal pice on side) less than 45” in height. Gate latches are all at least 54” in height. Gate is at least 48” in height, top horizontal is 45”.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Coping/bricks loose and coming out around pool at 4 FT depth marker. Deck cracking in back right corner, maintain less than 1/2" offset. Operator filled with caulk. Corrected. Advised monitoring deck for repairs. Chair within 5' of handrail. Operator moved and corrected. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. .2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Items within 3' of piping. Pool built '92. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Labels fading piping .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. Pool built 1992. .2513(b) Filter backwash shall be discharged through an air gap
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No floor drains in restroom. No hose bib in restroom within 50’ Pool built ‘92. .2526(c) Floor drains shall be provided in restrooms. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.