16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Gaps under fencing greater than 4" in some areas on hill. Maintain horizontals no less than 45" in height. Pool built '92, no permit action. Ensure windows onto pool deck do not open greater than 4" (unable to verify).
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Items within 3' of piping. Pool built '92.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Labels no longer visible on main drain piping .2518(d) Piping and valves shall be labeled with color codes or labels. Operator labeled and corrected. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash. Pool built 1992. .2513(b) Filter backwash shall be discharged through an air gap |