Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameWILDWOOD APARTMENTS
Address1022 FOREST OAK DRIVE
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/9/2021
Final Score @ Grade
12
General CommentsVisit to pool to lift Immediate Suspension and conduct pre-permit inspection for pool. Lifted Immediate Suspension for emergency phone and water quality. Chlorinator now working properly. Motor change has obtained permit on file for electrical work 5/21/21 E3879771. Records, loose coping, signage and chlorinator have been corrected since last inspection. Issued permit. Changed to "A" Open for Business. No Night Swimming. Note: main drains expire April 2022. Replace and submit updated PDSC for approval prior to expiration to avoid permit action. Contrasting color bands on stairs must be corrected by April 2022 for permit next year. Pool not heated. No signature due to COVID-19. Inspection with: Killian Lane Report to: wildwoodchl.mgr@ram-mgt.com

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No "No Diving" marker missing at 5 FT creating distance greater than 25 ft apart from other markers. .2523(d) The distance between no diving markers shall be no more than 25 feet perimeter or as the crow flies. .2523(d) No Diving markers shall be provided in all areas of the pool less than five feet deep. .2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. Operator stenciled "No Diving" in greater than 4" lettering on deck. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Gaps under fencing greater than 4" in some areas on hill. Maintain horizontals no less than 45" in height. Pool built '92, no permit action. Ensure windows onto pool deck do not open greater than 4" (unable to verify). .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Items within 3' of piping. Pool built '92. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. No hose bib on pool deck or in restrooms. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. Pool built prior to 2010, 1992. .2513(b) Filter backwash shall be discharged through an air gap