9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
"No Diving" marker missing at 5 FT creating distance greater than 25 ft apart from other markers. .2523(d) The distance between no diving markers shall be no more than 25 feet perimeter or as the crow flies.
.2523(d) No Diving markers shall be provided in all areas of the pool less than five feet deep.
.2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. Operator stenciled "No Diving" in greater than 4" lettering on deck. Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Gaps under fencing greater than 4" in some areas on hill. Maintain horizontals no less than 45" in height. Pool built '92, no permit action. Ensure windows onto pool deck do not open greater than 4" (unable to verify).
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Items within 3' of piping. Pool built '92.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
No hose bib on pool deck or in restrooms.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash. Pool built prior to 2010, 1992. .2513(b) Filter backwash shall be discharged through an air gap |