16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Brick wall and other parts of fencing creating horizontals (handholds/footholds) less than 45" in height. Bottom of fence broken in one area, creating gap greater than 4" at bottom. Pool built '92, no permit action. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". .2528(b) Horizontals shall not be located less than 45" in height.
*Note: Ensure windows onto pool deck from resident apartments do not open greater than 4" or have audible alarm. Did not verify at time of inspection. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Two bricks not secure, loose at time of inspection. .2537(3) There shall be no loose coping. Operator got supplies to secure brick coping. Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed flow meter stuck. .2518(g) Keep flow meter operational. Operator adjusted and corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Items within 3' of piping. Pool built '92.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Labels no longer visible on some piping .2518(d) Piping and valves shall be labeled with color codes or labels. Operator labeled and corrected. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash. Pool built '92.
.2513(b) Filter backwash shall be discharged through an air gap. |