47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
Walk in cooler gasket is torn, please replace.
4-501.11 - Good Repair and Proper Adjustment: Equipment components such as doors, seals, hinges, fasteners, and kick plates shall be kept intact, tight, and adjusted. |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
Holes in the FRP over the 3 compartment sink need to be filled. Cove at the walk in cooler door entrance is torn.
6-201.11 - Floors, Walls, and Ceilings: Establishment must provide floors, floor coverings, walls, wall coverings, and ceilings that are designed, constructed and installed so they are smooth and easily cleanable. Antislip floor coverings may be used for safety reasons. |