3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Pool pH at 6.8. Maintain at 7.2 to 7.8. Immediate Suspension issued. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Algae on pool walls and etching on pool plaster. Keep floors/walls clean and in good repair. Continue to monitor algae and treat as needed. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer baskets with some damage. Still operable. Continue to monitor and replace as needed. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Stair gate sticking on handrails outside of the barrier. Repair gate to self-close, self-latch. Sticks when partially opened. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck furniture < 6 ft. to pool edge. Maintain 6 ft. clearance around the swimming pool in all locations. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
No flow meter on chlorinator. Original construction. Install flow meter on inlet line to chlorinator per NSF approval.
Chlorine pucks in the skimmer baskets. Removed during the inspection. Considered an imminent hazard. Pool must be chlorinated through an approved chlorinator. Immediate Suspension issued. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Restrooms locked with no key for patrons. Operator stated restrooms were being kept locked due to homeless. Restrooms shall remain accessible at all times the pool is open to the public. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
No check valve visible on fill line to pool. Hose bib without backflow prevention device. Ensure water is from approved source. Provide backflow prevention per .2512. Original construction. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
Pool restroom without floor drain/hose bib. Original construction. Restrooms shall be equipped with floor drain and hose bib. |