Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHILTON HOTEL
Address8629 J M KEYNES DR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/5/2019
Final Score @ Grade
38
General CommentsImmediate Suspension issued for chlorine and for pool phone. Once corrected, please contact Katie Rudisill at 704-309-5494 to schedule a return inspection. Pool shall remain closed until a return visit has been made. Note - Main drains for pool expire in December 2020. Pool equalizers expire in May of 2020 and will require replacement prior to 2020 operating permit. Current covers are 6HPxxx. The new model of the 6HPxxx, 6HPHAxxx, has a lower flow rating at 92 gpm and will not be approved as a cover replacement for the current covers. The covers must be able to handle the maximum flow of the pump at 118 gpm.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Pool Chlorine at 0.2 ppm. Immediate Suspension issued. Maintain at least 1.0 ppm.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No log books and test kit reagents expired. Provide daily record keeping for chlorine, pH and main drain checks. Weekly akalinity and acid readings. Replace test kit reagents.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some algea build-up on pool walls. Keep clean and in good repair.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder rung 7" from pool wall. Maintain 3" to 6" from pool wall to ladder rung.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back gate with >1/2" within 18" of push bar at connection to fencing and also wall. Meshing greater than 1/2". Maintain no greater than 1/2" within 18" of latch mechanism. Door to stairwell without latching mechanism. Repair to self-close, self-latch or self-close with audible alarm. Horizontals on fencing that connects into pool barrier wall provides footholds. Eliminate footholds. Fence pre-2010.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool furniture 5 ft. to pool edge. Maintain at least 6 ft. clearance around pool in all locations.
22 6 Premises: emergency telephone provided No No No 911 has no address populating when called. Phone number listed dials back to entering a mailbox number. 911 must have correct address and phone number. Must match what is posted. Immediate Suspension issued.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Keep operational.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Over the rim fill spout protrudes >2" over edge of deck into pool. Repair to 2" or less extension past the pool coping edge.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No Pool restroom without hose bib or floor drain. Original construction. Provide floor drain and hose bib in pool restrooms.